Diesel Generator
The Engine
The 3412 Series engines continue to offer users a durable and
dependable power package for many of the worlds toughest applications.
The stringent design objectives for CAT 3412 Series engines included
application flexibility, fuel efficiency, ease of maintenance and
repair.
Performance and Reliability
The 3412 is a 27 litre displacement engine, V12 configuration with a
137mm bore and 152mm stroke length. Since its introduction, the 3412
has become the standard power unit for many high load factor
applications. These engines meet current Indian emission norms.
The Package Generator
Caterpillar generator sets
are packaged at the state-of-the-art packaging facility of Caterpillar
Power India Private Limited (CPIPL), with load banks, twin beds, sound
treated test cell and paralleling facility. They are completely
configured and come with an acoustic enclosure. Their perfect packaging
in a compact design enables easy installation, operation and
maintenance.
The AC Generators
AC generators are double bearing, star connected, self-excited and
self-regulated, brushless, with Class H insulation and Class H temp
rise and are designed and manufactured for Caterpillar and meet the
following specifications: IS 4722, BS:5000, IEC34-1. Load Adjustment
Module (LAM) provides engine relief upon sudden block loading, improves
load acceptance and recovery time.
Diagnostics and Monitoring
Caterpillar Electronic Modular Control Panel (EMCP) is a generator set
mounted control panel. EMCP is an environmentally sealed, solid-state,
microprocessor-based module for engine control and AC metering. Known
for its unfailing durability, precise metering and state-of-the-art
sensors, diagnostics and protective features, clear, descriptive
graphics and easy-reading LEDs. The EMCP gives you all that, and much
more: Information, Protection, Flexibility and Convenience.
Noise Enclosure
CAT noise enclosure is a containerized design, sturdy and
weather-resistant to ensure durability for all weather conditions. Made
of non-igniting and self-extinguishing acoustic mineral wool of 50mm
thick which is used for noise and thermal insulation in addition to
resin bonding having a 96 kg/m3 density. These are specially designed
for easy installations, maintenance of DG set and access for all tie
points.
Engine Model |
kVA |
ekW |
Speed |
No. of Cylinders |
Bore |
Stroke |
Disp |
|
3412 DITA-GP-3
|
725 |
580 |
1500 |
12 |
137 |
152 |
27.0 |
|